Downloads
Here you can download our documents, images, videos, software or presentations. Click the tag to filter all resources including the clicked tag. To narrow your search, choose multiple tags. View all files below the wanted group title by clicking the link View all.
Search by tags
Datasheets TWIG Eon
View allFlyers TWIG Neo
View allFlyers TWIG One
View allDatasheets TWIG Neo
View allDatasheets TWIG One
View allDatasheets TWIG One Ex
View allDatasheets TWIG Accessories
View allDatasheets TWIG Easy
View allDatasheets TWIG SOSCard
View allDatasheets TWIG Beacon
View all
TWIG Beacon Datenblatt EZ3415-DE
00:10
0
0
TWIG Beacon Scheda tecnica EZ3415-IT
00:10
0
0
Datasheets TWIG Beacon Ex
View allDatasheets TWIG Tag
View allDatasheets TWIG Remote Button
View allDatasheets TWIG Door Sensor
View allDatasheets TWIG Bracer
View allDatasheets TWIG SRD
View allDatasheets TWIG Point
View allApplication Instructions for Wi-Fi communication
View allDeclarations of Conformity en
View all
Declaration of Conformity ATEX TCP90EU TWIG Protector Ex
Preview
Declaration of Conformity - DoC TWIG Protector Ex IIC ATEX Directive 94/9/EC
00:00
0
0
Case Studies
View all
00:00
0
0
Certificates
View all
Quality Certificate ATEX Directive 94/9/EC
Preview
Certificate - Quality Certificate ATEX Directive 94/9/EC
00:00
0
0
Johtamisjärjestelmäsertifikaatti ISO14001:2015
Preview
Certificate - Johtamisjärjestelmäsertifikaatti ISO14001:2015
00:00
0
0
00:00
0
0
Safety Instructions en-de-es-fr-it-nl-no-sv-fi
View allDirectives en
View allRegulations en
View allTerms and policies en
View allPresentations en
View allLeaflets
View allVideos
View all
How to use man down alarm?
Preview
Man Down alarm system is a sensor based aid to launching emergency cycle that makes automatic call and sends position to predefined numbers in case the user is unable to trigger alarm manually.
Read more about TWIG ManDown alarm on: https://www.twigcom.com/page/mandown-alarm-for-lone-workers
TWIG personal alarm devices support Man Down alarm triggered by 4 independent alert triggers: device orientation, non-movement, free fall and impact.
Alert is launched when predefined parameters are met. In order to minimize false alarms or missing alarms, the Man Down settings need to be carefully matched with the usage scenario and environment. The user needs to be trained on Man Down function and also on understanding its limitations.
Man Down alarm triggered by falling AND no movement
Horizontal + Motion Sensitivity Enabled: TWIG SOS cycle is launched when device main axis orientation deviates from absolute upright position more than Tilt Angle (in degrees), AND detected device movement (acceleration) falls below a threshold value defined by Motion Sensitivity.
Vertical + Motion Sensitivity Enabled : Man Down alert launches TWIG SOS cycle when device beam axis orientation deviates from absolute upright position more than Tilt Angle (in degrees), AND detected device movement (acceleration) falls below a threshold value defined by Motion Sensitivity.
Man Down alert is triggered when both rules are met:
- device main or beam axis orientation deviates from absolute upright position and
- device movement falls below a threshold value defined by motion sensitivity.
Man Down+ alarm triggered by falling OR no movement
TWIG personal alarms supporting Man Down+ feature alerts the ARC also in situations where the user is not moving (e.g. because of unconsciousness) but the personal alarm is not deviating enough from the absolute tilt angle (e.g. where fainting doesn’t include falling and change in device orientation axis). In situation of no movement SOS cycle is launched when detected device movement (acceleration) falls below a threshold value defined by Motion Sensitivity. Device orientation has no effect.
Man Down++ alarm triggered by free fall or impact
The TWIG personal alarms supporting Man Down++ feature alerts the ARC also in situations of a sudden impact or free falling.
Read more about TWIG ManDown alarm on: https://www.twigcom.com/page/mandown-alarm-for-lone-workers
TWIG personal alarm devices support Man Down alarm triggered by 4 independent alert triggers: device orientation, non-movement, free fall and impact.
Alert is launched when predefined parameters are met. In order to minimize false alarms or missing alarms, the Man Down settings need to be carefully matched with the usage scenario and environment. The user needs to be trained on Man Down function and also on understanding its limitations.
Man Down alarm triggered by falling AND no movement
Horizontal + Motion Sensitivity Enabled: TWIG SOS cycle is launched when device main axis orientation deviates from absolute upright position more than Tilt Angle (in degrees), AND detected device movement (acceleration) falls below a threshold value defined by Motion Sensitivity.
Vertical + Motion Sensitivity Enabled : Man Down alert launches TWIG SOS cycle when device beam axis orientation deviates from absolute upright position more than Tilt Angle (in degrees), AND detected device movement (acceleration) falls below a threshold value defined by Motion Sensitivity.
Man Down alert is triggered when both rules are met:
- device main or beam axis orientation deviates from absolute upright position and
- device movement falls below a threshold value defined by motion sensitivity.
Man Down+ alarm triggered by falling OR no movement
TWIG personal alarms supporting Man Down+ feature alerts the ARC also in situations where the user is not moving (e.g. because of unconsciousness) but the personal alarm is not deviating enough from the absolute tilt angle (e.g. where fainting doesn’t include falling and change in device orientation axis). In situation of no movement SOS cycle is launched when detected device movement (acceleration) falls below a threshold value defined by Motion Sensitivity. Device orientation has no effect.
Man Down++ alarm triggered by free fall or impact
The TWIG personal alarms supporting Man Down++ feature alerts the ARC also in situations of a sudden impact or free falling.
00:00
0
0
TWIG One and TWIG One Ex personal alarm devices
Preview
Copy link for download:
ftp://ftp.twigcom.com/PublicDocuments/Videos/TWIG_One_and_TWIG_One_Ex_Animation_with_text.mp4
ftp://ftp.twigcom.com/PublicDocuments/Videos/TWIG_One_and_TWIG_One_Ex_Animation_with_text.mp4
00:00
0
0
TWIG Point service provider platform for TWIG personal alarms
Preview
TWIG Point SP is a modular suite of cloud services to manage and monitor TWIG personal alarm devices. Deployed internationally in minutes, the TWIG Point SP combines ease of use and remote device management with powerful features such as location fusion, custom floor plans and API.
00:00
0
0
TWIG personal alarms for risky lone worker situations
Preview
Video about TWIG personal alarms in Italian made by Italian TWIG distributor.
00:00
0
0