Canale pubblico
Ultimo aggiornamento:
03/11/2021
TWIG Point service provider platform for TWIG personal alarms
3655 Visualizzazioni •Protecting people is our priority
0 Visualizzazioni •TWIG Point -pilvipalvelut TWIG-henkilöhälytinten valvontaan ja hallintaan
3323 Visualizzazioni •TWIG Embody - the wearable 3G/GSM/GNSS personal alarm device
4593 Visualizzazioni •TWIG Embody le dispositif d'alarme - vidéo en français
4672 Visualizzazioni •TWIG Embody personlarm - video på svenska
5008 Visualizzazioni •TWIG Embody das 3G/GSM/GNSS Personen-Notsignalgerät Video auf Deutsch
5127 Visualizzazioni •TWIG One and TWIG One Ex personal alarm devices
6800 Visualizzazioni •Twig One and TWIG One Ex Animation without text
3851 Visualizzazioni •TWIG Neo marketing video
2984 Visualizzazioni •TWIG Neo video short version
3898 Visualizzazioni •TWIG personal alarms for risky lone worker situations
2282 Visualizzazioni •How to use man down alarm?
2722 Visualizzazioni •TWIG Configuration Guide YZ6501-EN
14795 Visualizzazioni •TWIG Configurator
12846 Visualizzazioni •Case Study: TWIG Embody protecting lone workers in indoor emergency situations
12817 Visualizzazioni •REACH Regulation (EC) No 1907/2006 EN
10328 Visualizzazioni •Twig Com Terms of Trade
8706 Visualizzazioni •TWIG Accessories Datasheet EZ6300-EN
7242 Visualizzazioni •TWIG_Configuration_Guide_YZ3501-08-EN
7152 Visualizzazioni •TWIG Privacy Policy
7035 Visualizzazioni •Declaration of Conformity RED TUP91EU TWIG Embody
7018 Visualizzazioni •TWIG FirmwareLoader
6882 Visualizzazioni •ATEX_Safety_instructions_YZ5406-02-EN-DE-ES-FR-IT-NL-NO-SV-FI
6865 Visualizzazioni •TWIG SOSCard Kurzanleitung YZ4700-DE
6844 Visualizzazioni •TWIG One and TWIG One Ex personal alarm devices
6800 Visualizzazioni •TWIG Protector Ex Kurzanleitung YZ5600-DE
6756 Visualizzazioni •TWIG Embody Kurzanleitung YZ4600-13-DE
6585 Visualizzazioni •TWIG Beacon Ex SRD Kurzanleitung YZ3445-DE
6542 Visualizzazioni •TWIG Beacon SRD Kurzanleitung YZ3415-DE
6473 Visualizzazioni •TWIG Bracer Datasheet EZ6000-EN
6471 Visualizzazioni •RoHS2 Directive EN
6392 Visualizzazioni •TWIG Protector EasyS Kurzanleitung YZ5400-DE
6361 Visualizzazioni •How to use man down alarm?
Man Down alarm system is a sensor based aid to launching emergency cycle that makes automatic call and sends position to predefined numbers in case the user is unable to trigger alarm manually.
Read more about TWIG ManDown alarm on: https://www.twigcom.com/page/mandown-alarm-for-lone-workers
TWIG personal alarm devices support Man Down alarm triggered by 4 independent alert triggers: device orientation, non-movement, free fall and impact.
Alert is launched when predefined parameters are met. In order to minimize false alarms or missing alarms, the Man Down settings need to be carefully matched with the usage scenario and environment. The user needs to be trained on Man Down function and also on understanding its limitations.
Man Down alarm triggered by falling AND no movement
Horizontal + Motion Sensitivity Enabled: TWIG SOS cycle is launched when device main axis orientation deviates from absolute upright position more than Tilt Angle (in degrees), AND detected device movement (acceleration) falls below a threshold value defined by Motion Sensitivity.
Vertical + Motion Sensitivity Enabled : Man Down alert launches TWIG SOS cycle when device beam axis orientation deviates from absolute upright position more than Tilt Angle (in degrees), AND detected device movement (acceleration) falls below a threshold value defined by Motion Sensitivity.
Man Down alert is triggered when both rules are met:
- device main or beam axis orientation deviates from absolute upright position and
- device movement falls below a threshold value defined by motion sensitivity.
Man Down+ alarm triggered by falling OR no movement
TWIG personal alarms supporting Man Down+ feature alerts the ARC also in situations where the user is not moving (e.g. because of unconsciousness) but the personal alarm is not deviating enough from the absolute tilt angle (e.g. where fainting doesn’t include falling and change in device orientation axis). In situation of no movement SOS cycle is launched when detected device movement (acceleration) falls below a threshold value defined by Motion Sensitivity. Device orientation has no effect.
Man Down++ alarm triggered by free fall or impact
The TWIG personal alarms supporting Man Down++ feature alerts the ARC also in situations of a sudden impact or free falling.
Read more about TWIG ManDown alarm on: https://www.twigcom.com/page/mandown-alarm-for-lone-workers
TWIG personal alarm devices support Man Down alarm triggered by 4 independent alert triggers: device orientation, non-movement, free fall and impact.
Alert is launched when predefined parameters are met. In order to minimize false alarms or missing alarms, the Man Down settings need to be carefully matched with the usage scenario and environment. The user needs to be trained on Man Down function and also on understanding its limitations.
Man Down alarm triggered by falling AND no movement
Horizontal + Motion Sensitivity Enabled: TWIG SOS cycle is launched when device main axis orientation deviates from absolute upright position more than Tilt Angle (in degrees), AND detected device movement (acceleration) falls below a threshold value defined by Motion Sensitivity.
Vertical + Motion Sensitivity Enabled : Man Down alert launches TWIG SOS cycle when device beam axis orientation deviates from absolute upright position more than Tilt Angle (in degrees), AND detected device movement (acceleration) falls below a threshold value defined by Motion Sensitivity.
Man Down alert is triggered when both rules are met:
- device main or beam axis orientation deviates from absolute upright position and
- device movement falls below a threshold value defined by motion sensitivity.
Man Down+ alarm triggered by falling OR no movement
TWIG personal alarms supporting Man Down+ feature alerts the ARC also in situations where the user is not moving (e.g. because of unconsciousness) but the personal alarm is not deviating enough from the absolute tilt angle (e.g. where fainting doesn’t include falling and change in device orientation axis). In situation of no movement SOS cycle is launched when detected device movement (acceleration) falls below a threshold value defined by Motion Sensitivity. Device orientation has no effect.
Man Down++ alarm triggered by free fall or impact
The TWIG personal alarms supporting Man Down++ feature alerts the ARC also in situations of a sudden impact or free falling.