Canal público

Canal público

Here you can download our documents, images, videos, software or presentations. Click the tag to filter all resources including the clicked tag. To narrow your search, choose multiple tags. View all files below the wanted group title by clicking the link View all.

TWIG Easy images
Ver todos
TWIG short range devices SRD images
Ver todos
TWIG One Ex images
Ver todos
TWIG One images
Ver todos
Instructies en handleidingen NL
Ver todos
Gegevensbladen nl
Ver todos
Istruzioni e guide IT
Ver todos
TWIG_Protector_Pro_Guida_rapida_YZ5500-01-IT
Vista previa gratuita
TWIG Protector Pro Quick Guide IT
TWIG_Protector_Pro_Ex_Guida_rapida_YZ5700-05-IT
Vista previa gratuita
TWIG Protector Pro Ex Quick Guide IT
Instruktioner och handböcker SV
Ver todos
Flyers de
Ver todos
Software
Ver todos
TWIG SRD Configurator
Vista previa gratuita
TWIG Configurator
Vista previa gratuita
TWIG FirmwareLoader
Vista previa gratuita
Flyers en
Ver todos
TWIG Neo Flyer FZ6710-EN
Vista previa gratuita
Certificates en
Ver todos
Johtamisjärjestelmäsertifikaatti ISO14001:2015
Vista previa gratuita
Certificate - Johtamisjärjestelmäsertifikaatti ISO14001:2015
Management System Certificate ISO14001 2015
Vista previa gratuita
Certificate - Environmental Certificate ISO14001:2015
Johtamisjärjestelmäsertifikaatti ISO9001:2015
Vista previa gratuita
Certificate - Johtamisjärjestelmäsertifikaatti ISO9001:2015
Management System Certificate ISO9001:2015
Vista previa gratuita
Certificate - Quality Certificate ISO9001:2015
Safety Instructions en-de-es-fr-it-nl-no-sv-fi
Ver todos
ATEX_Beacon_Safety_instructions_YZ3447-01-EN-DE-ES-FR-IT-NL-NO-SV-FI
Vista previa gratuita
Safety Instructions - ATEX Beacon Safety instructions YZ3447-01-EN-DE-ES-FR-IT-NL-NO-SV-FI
ATEX_Safety_instructions_YZ5406-02-EN-DE-ES-FR-IT-NL-NO-SV-FI
Vista previa gratuita
Safety Instructions - ATEX Safety instructions YZ5406-02-EN-DE-ES-FR-IT-NL-NO-SV-FI
Posters en
Ver todos
TWIG poster A1 TWIG One
Vista previa gratuita
TWIG poster A1 TWIG Neo
Vista previa gratuita
Directives en
Ver todos
Radio Equipment Directive RED
Vista previa gratuita
RED
RoHS2 Directive EN
Vista previa gratuita
RoHS2 Directive EN
RoHS1 Directive EN
Vista previa gratuita
RoHS1 Directive EN
ATEX Workplace Directive EN
Vista previa gratuita
ATEX Workplace Directive EN
Regulations en
Ver todos
REACH Regulation (EC) No 1907/2006 EN
Vista previa gratuita
REACH Regulation (EC) No 1907/2006 EN
Terms and policies en
Ver todos
TWIG Privacy Policy
Vista previa gratuita
Twig Com End User Terms of Service
Vista previa gratuita
Twig Com End User Terms of Service
Twig Com Service Level Agreement
Vista previa gratuita
Twig Com Service Level Agreement
Presentations en
Ver todos
TWIG_2020_presentation_EN_PDF
Vista previa gratuita
TWIG 2020 presentation English
TWIG_2020_presentation_FI_PDF
Vista previa gratuita
TWIG 2020 presentation Finnish
TWIG_2020_presentation_DE_PDF
Vista previa gratuita
TWIG 2020 presentation German
Leaflets en
Ver todos
TWIG Point SP SaaS Leaflet EZ-1200-EN
Vista previa gratuita
version 2
TWIG_Ohjelmistot_ja_Palvelut_Lehtinen_EZ1000-05-FI
Vista previa gratuita
Leaflet - TWIG Ohjelmistot ja Palvelut Lehtinen EZ1000-05-FI
TWIG_Software_and_Services_Leaflet_EZ1000-05-EN
Vista previa gratuita
Leaflet - TWIG Software and Services Leaflet EZ1000-05-EN
Videos en
Ver todos
Protecting people is our priority
Vista previa gratuita
The rise of lone working

Lone working is increasing globally, and it poses a unique set of risks for both workers and companies. In the event of an accident or emergency, help may not be readily available.
Lone working is prevalent in many industries, such as manufacturing, property maintenance and healthcare.

The importance of feeling safe

Feeling safe is important for everyone.
By protecting your company's most valuable asset - your employees - you help promote efficient work and peace of mind.

The guardians of lone worker safety

Here in Finland we are the happiest people in the world. We are happy because we know what it means to be prepared.

It is no accident that first rescue phones were invented in Finland. We know how to engineer and manufacture high-quality lone worker alarm devices for the safety of people.

Our modern production line enables efficient manufacturing that meets the most demanding quality requirements. Each device is thoroughly tested to ensure high quality and functionality in case of an accident.

We maintain a comprehensive component warehouse to ensure prompt deliveries that meet our customer needs.

Protecting people is our priority

When it comes to individual safety and wellbeing, we leave nothing to chance. TWIG lone worker alarms are trusted by our partners across a range of demanding industries.

Our high-quality solutions ensure the security and safety of hundreds of thousands of lone workers in various industries every day.

Let's make working alone safer together!
How to use man down alarm?
Vista previa gratuita
Man Down alarm system is a sensor based aid to launching emergency cycle that makes automatic call and sends position to predefined numbers in case the user is unable to trigger alarm manually.

Read more about TWIG ManDown alarm on: https://www.twigcom.com/page/mandown-alarm-for-lone-workers

TWIG personal alarm devices support Man Down alarm triggered by 4 independent alert triggers: device orientation, non-movement, free fall and impact.

Alert is launched when predefined parameters are met. In order to minimize false alarms or missing alarms, the Man Down settings need to be carefully matched with the usage scenario and environment. The user needs to be trained on Man Down function and also on understanding its limitations.

Man Down alarm triggered by falling AND no movement

Horizontal + Motion Sensitivity Enabled: TWIG SOS cycle is launched when device main axis orientation deviates from absolute upright position more than Tilt Angle (in degrees), AND detected device movement (acceleration) falls below a threshold value defined by Motion Sensitivity.

Vertical + Motion Sensitivity Enabled : Man Down alert launches TWIG SOS cycle when device beam axis orientation deviates from absolute upright position more than Tilt Angle (in degrees), AND detected device movement (acceleration) falls below a threshold value defined by Motion Sensitivity.

Man Down alert is triggered when both rules are met:
- device main or beam axis orientation deviates from absolute upright position and

- device movement falls below a threshold value defined by motion sensitivity.

Man Down+ alarm triggered by falling OR no movement

TWIG personal alarms supporting Man Down+ feature alerts the ARC also in situations where the user is not moving (e.g. because of unconsciousness) but the personal alarm is not deviating enough from the absolute tilt angle (e.g. where fainting doesn’t include falling and change in device orientation axis). In situation of no movement SOS cycle is launched when detected device movement (acceleration) falls below a threshold value defined by Motion Sensitivity. Device orientation has no effect.

Man Down++ alarm triggered by free fall or impact
The TWIG personal alarms supporting Man Down++ feature alerts the ARC also in situations of a sudden impact or free falling.
TWIG personal alarms for risky lone worker situations
Vista previa gratuita
Video about TWIG personal alarms in Italian made by Italian TWIG distributor.
TWIG Neo video short version
Vista previa gratuita
The new, small and scalable TWIG Neo provides multiple wearing options making it ideal e.g. for laboratory, maintenance and health care staff.

TWIG Neo adds new features to wearable TWIG devices: 4G data communication, configurable UI and keypad, SRD3 option, robust SIM cradle and Firmware over-the-air.

With SRD3 option TWIG Neo is the first multi-wearable TWIG device to benefit from TWIG Point Netloc hybrid location both for public space location (cellular + Wi-Fi) and for on-site location (TWIG SRD + Wi-Fi + BLE).
Datasheets for TUP90EU and older devices en-de-es-it
Ver todos
Ficha_de_datos_de_TWIG_Protector_Ex_EZ3404-02-ES
Vista previa gratuita
Datasheets for TUP90EU and older devices - Ficha de datos de TWIG Protector Ex EZ3404-02-ES
TWIG_Protector_Scheda_tecnica_EZ3300-02-IT
Vista previa gratuita
Datasheets for TUP90EU and older devices - TWIG Protector Scheda tecnica EZ3300-02-IT
TWIG_Protector_Pro_Scheda_tecnica_EZ3500-02-IT
Vista previa gratuita
Datasheets for TUP90EU and older devices - TWIG Protector Pro Scheda tecnica EZ3500-02-IT
Ficha_de_datos_de_TWIG_Protector_Pro_EZ3500-02-ES
Vista previa gratuita
Datasheets for TUP90EU and older devices - Ficha de datos de TWIG Protector Pro EZ3500-02-ES
Manuals for TUP90EU and older devices en-fr-sv-fi
Ver todos
TWIG_WebFinder_QuickGuide_YZ3070-1-EN
Vista previa gratuita
Manuals for TUP90EU and older devices - TWIG WebFinder QuickGuide YZ3070-1-EN
TWIG_Discovery_Pro_UserManual_YZ3033-1-EN
Vista previa gratuita
Manuals for TUP90EU and older devices - TWIG Discovery Pro UserManual YZ3033-1-EN
TWIG_Protector_Ex_Quick_Guide_YZ3404-02-EN
Vista previa gratuita
Manuals for TUP90EU and older devices - TWIG Protector Ex Quick Guide YZ3404-02-EN
TWIG_Protector_EasyS_EasyP_Quick_Guide_YZ3310-06-EN
Vista previa gratuita
Manuals for TUP90EU and older devices - TWIG Protector EasyS EasyP Quick Guide YZ3310-06-EN
Configuration Guides for device types TCP90EU en-fr
Ver todos
TWIG_Configuration_Guide_YZ3501-06-FR
Vista previa gratuita
Configuration Guides for device types TCP90EU - TWIG Configuration Guide YZ3501-06-FR
TWIG_Configuration_Guide_YZ3501-08-EN
Vista previa gratuita
Configuration Guides for device types TCP90EU - TWIG Configuration Guide YZ3501-08-EN
Information
Ver todos
TWIG documents and images
Vista previa gratuita